Power quality, grounding & UPS handbook. Vol. 9 / edited by Randolph W. Hurst.

Contributor(s): Hurst, Randolph W.
Material type: materialTypeLabelBookPublisher: Pickering, On : The Electricity Forum, 2008Description: 128 p. : ill. (some col.) ; 28 cm. + pbk.ISBN: 9781897474068 .Subject(s): Uninterruptible power supply | Electric power systems -- Electric losses | Electric power system stability | Electric power systems -- Protection | Electric power system stability | Electric wiring -- Safety measuresDDC classification: 621.3192
Contents:
Why grounding is used -- Avoid electrical ground loops / Dave Harrold -- Electrical grounding techniques / LEM Instruments Inc. -- Inter-system ground noise: cause and effects / American Power Conversion -- Effective grounding and bonding / Keith Switzer -- Reducing ground balance in DC-to-DC converters - some grounding essentials / Jeff Barrow -- Reliabillity models for electric power systems / American Power Conversion -- The role of testing in the practice of good grounding / Jeffrey R. Jowett, Megger -- Transient overvoltages -- Neutral-to-ground voltage causes and cures / George Lannert -- What's your power quality problem? / S & C Electric Company -- Power quality application guide - adjustable speed drive / B C Hydro -- What causes power quality problems? / Computer Power & Consulting -- Deep earth grounding vs. shallow earth grounding / Martin D. Conroy and Paul G. Richard -- Transient voltage surge suppression (TVSS) for commercial/residential applications / BC Hydro -- Flicker -- Power quality: a guide to voltage fluctuation and light flicker / BC Hydro -- Noise and shielding / Kim Fowler -- Voltage sags (dips) and swells / Alex McEachern -- Power quality for your local area network (LAN) / BC Hydro -- Power quality and power factor correction -- A guide to power and UPS terms / Peter Nystrom -- Voltage regulation -- Uninterruptible power supply / BC Hydro -- Harmonics -- Effect of rooftop exposure on ambient temperatures inside conduits / Travis C. Lindsey, William T. Black and Peter A. Sharpe -- Buyer's guide.
Holdings
Item type Current library Call number Copy number Status Barcode
General lending MTU Bishopstown Library Lending 621.3192 (Browse shelf(Opens below)) 1 Available 00131914
Total holds: 0

Includes bibliographical references.

Why grounding is used -- Avoid electrical ground loops / Dave Harrold -- Electrical grounding techniques / LEM Instruments Inc. -- Inter-system ground noise: cause and effects / American Power Conversion -- Effective grounding and bonding / Keith Switzer -- Reducing ground balance in DC-to-DC converters - some grounding essentials / Jeff Barrow -- Reliabillity models for electric power systems / American Power Conversion -- The role of testing in the practice of good grounding / Jeffrey R. Jowett, Megger -- Transient overvoltages -- Neutral-to-ground voltage causes and cures / George Lannert -- What's your power quality problem? / S & C Electric Company -- Power quality application guide - adjustable speed drive / B C Hydro -- What causes power quality problems? / Computer Power & Consulting -- Deep earth grounding vs. shallow earth grounding / Martin D. Conroy and Paul G. Richard -- Transient voltage surge suppression (TVSS) for commercial/residential applications / BC Hydro -- Flicker -- Power quality: a guide to voltage fluctuation and light flicker / BC Hydro -- Noise and shielding / Kim Fowler -- Voltage sags (dips) and swells / Alex McEachern -- Power quality for your local area network (LAN) / BC Hydro -- Power quality and power factor correction -- A guide to power and UPS terms / Peter Nystrom -- Voltage regulation -- Uninterruptible power supply / BC Hydro -- Harmonics -- Effect of rooftop exposure on ambient temperatures inside conduits / Travis C. Lindsey, William T. Black and Peter A. Sharpe -- Buyer's guide.